How to use vacuum drying oven

How to use vacuum drying oven

1. Use environment requirements:

a) Temperature: 5 ~ 40 ℃

b) Relative humidity: ≤85% RH

c) Power supply voltage: AC220V ± 10% 50Hz

d) No strong vibration and corrosive gas around

2. Vacuum debugging:

a) Close the box door and tighten the door handle in place, close the bleed valve (turn the hole on the rubber plug and the hole on the bleed valve 90 °), and open the vacuum valve (rotate 90 ° counterclockwise). The vacuum valve may be tightly opened and closed after one use.

b) Connect the vacuum tube of the vacuum drying box (outer diameter: Φ16mm) and vacuum pump (type 2XZ-2, outer diameter Φ16mm) with the vacuum connecting tube (inner diameter: Φ16mm wall thickness: 10mm) of the random accessories (6090 and 6210 type) Connected). Turn on the power of the vacuum pump and start pumping. When the indication value of the vacuum gauge reaches -0.1Mpa, first turn off the vacuum valve and then turn off the power of the vacuum pump to prevent the backflow of the vacuum pump oil into the working chamber. (6090 and 6210 without vacuum valve can be directly closed The vacuum pump power supply on the panel) is now in a vacuum state inside the box.

3. Commissioning of vacuum box:

After the vacuum degree debugging is completed, the following operations can be performed:

a. Turn on the power supply of the vacuum box, at this time, the power indicator light should be on (6090 and 6210 models should be turned on respectively). The temperature control instrument is powered on and self-test. temperature. The AT and HEAT lights on the temperature controller should be on, indicating that the instrument is in the heating state.

b. Modify the set temperature

1. Press the function key (SET) of the temperature control instrument; after the SP character is displayed on the PV screen, you can use the key button to modify the set temperature (6090 and 6210 models should be set and modified for 2 and 3 instruments respectively, the following categories with).

2. After the modification is completed, press the SET button again, the PV screen displays ST characters, and set the timing time.

If you do not use the timing function, still let it be ST = 0

3. Press the SET button again to make the PV screen display the studio temperature, and the SV screen displays the new set temperature. The AT and HEAT lights of the instrument are on, and then the instrument enters the heating state again.

c. When the temperature in the working room is close to the set temperature, the HEAT light flashes on and off, indicating that the heating has entered the PID adjustment stage. Sometimes the instrument's measured temperature exceeds the set temperature, and sometimes it is normal. When the measured temperature is close to or equal to the set temperature, the studio will enter a constant temperature state after 1 ~ 2h, and the items will enter the drying stage.

d. When the required temperature is low, the secondary setting method can be adopted. For example, if the required operating temperature is 70 ℃, the first setting is 60 ℃. After the temperature overshoot starts to fall back, the second setting is 70 ℃. , This can reduce or even eliminate the temperature overshoot phenomenon, and enter the constant temperature state as soon as possible.

e. When the items are dry, turn off the power. If the temperature is accelerated, open the air release valve to make the vacuum level 0. Wait about 5 minutes before opening the door.

4. If the humidity of the dry matter in the working room is high, the generated water vapor will affect the performance of the vacuum pump. It is recommended to put a "drying / filter" between the drying box and the vacuum pump. Our company can equip a dryer with external dimension of Φ120 × 300mm and external diameter of Φ16 as required.

5. If you need to add inert gas such as nitrogen during the process of drying the items, you should specify in the contract and add an intake valve.

(note:

1. If the vacuum pump is normal and meets the technical requirements and cannot be evacuated, open the door of the box and use the wrench in the product accessories to twist the door buckle in the box one turn to shorten and close the door again.

2. This vacuum drying oven can not be used as an electric heating oven, because the studio is not in a vacuum state, the measurement temperature and the actual temperature in the working room have a great error)

It is essential for cat owners to have cat litter box at their home, as cats are self-maintained pets that go to toilets by themselves. We supply many different sizes and shapes of cat litter box in our range that you can fulfill the needs of different cat owners. Cat litter scoops are also included in the range to go with the cat litter box.

Cat litter box

Cat litter scoop

 

Cats naturally groom themselves, however, we also provide cat slicker brush with round pointed tips for cat owners to groom and massage their cats at the same time.

Cat slicker brush




ABOUT US


PERCELL PET is established in 1978 with offices located in Taipei, Taiwan and Guangdong, China. Currently, Percell Pet partners with more than 49 distributors around the world and carries thousands of quality pet supplies for dogs, cats, birds, fresh and salt water fishes, reptiles and small animals, like rabbits and ferrets, etc from Taiwan and China.


We supply popular and classic pet products around the world and also OEM products at your needs.


  • FLEXIBLE IN ORDER VOLUME, orders can be done in LCL or full container, MOQ can be discussed accordingly.
  • COMMUNICATION, staffs are fluent in written English with in time replies.
  • SERVICE, provide help and solutions to your sourcing in Taiwan and China.



Cat Grooming & Hygiene

Cat Grooming Tool,Cats Hygiene Spray,Cat Grooming Comb,Cat Grooming Scissor

PERCELL PET SYSTEM CO., LTD , https://www.percell-pet.com