Human chemerin enzyme-linked immunoassay (ELISA) kit instructions for use This reagent is for research use only: This kit is used to determine the content of chemerin in human serum, plasma and related liquid samples. Experimental principle: This kit uses the double antibody sandwich method to determine the level of human chemerin in the specimen. The microplate is coated with purified human chemerin antibody to make a solid-phase antibody. Chemerin is added to the monoclonal antibody-coated microwells in turn, and then combined with the HRP-labeled chemerin antibody to form an antibody-antigen-enzyme-labeled antibody complex. After thorough washing, add substrate TMB to develop color. TMB is converted into blue under the catalysis of HRP enzyme, and into the final yellow under the action of acid. The color depth is positively correlated with the chemerin in the sample. The absorbance (OD value) was measured with a microplate reader at a wavelength of 450 nm, and the concentration of human chemerin in the sample was calculated by a standard curve. Kit composition: kit composition 48 well configuration 96 well configuration storage instructions 1 copy 1 copy sealing film 2 pieces (48) 2 pieces (96) 1 sealed bag 1 enzyme coated plate 1 × 48 1 × 96 2 Store standard at -8 ° C: 54ng / L 0.5ml × 1 bottle 0.5ml × 1 bottle at 2-8 ° C Store standard dilution 1.5ml × 1 bottle 1.5ml × 1 bottle at 2-8 ° C Store enzyme label reagent 3 ml × 1 bottle of 6 ml × 1 bottle of sample diluent at 2-8 ° C 3 ml × 1 bottle of 6 ml × 1 bottle of 2-8 ° C Developer A 3 ml × 1 bottle of 6 ml × 1 bottle of 2-8 ° C Developer B solution 3 ml × 1 bottle 6 ml × 1 bottle at 2-8 ° C Storage stop solution 3ml × 1 bottle 6ml × 1 bottle 2-8 ° C Store 20 times concentrated washing solution 20ml × 1 bottle 30ml × 1 bottle 2- Sample handling and requirements for storage at 8 ° C: 1. Serum: room temperature blood coagulates naturally for 10-20 minutes, centrifuged for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully and centrifuge again if a precipitate appears during storage. 2. Plasma: EDTA or sodium citrate should be selected as the anticoagulant according to the requirements of the specimen, mixed for 10-20 minutes, and centrifuged for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. If a precipitate forms during storage, it should be centrifuged again. 3. Urine: collected in a sterile tube and centrifuged for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. If a precipitate forms during storage, centrifuge again. Pleural and ascites, cerebrospinal fluid reference implementation. 4. Cell culture supernatant: When detecting secreted components, collect with a sterile tube. Centrifuge for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. When detecting the components inside the cells, dilute the cell suspension with PBS (PH7.2-7.4), and the cell concentration will reach about 1 million / ml. Through repeated freezing and thawing, the cells are destroyed and the intracellular components are released. Centrifuge for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. If a precipitate forms during storage, it should be centrifuged again. 5. Organize the specimen: after cutting the specimen, weigh it. Add a certain amount of PBS, PH7.4. Quickly freeze and save with liquid nitrogen for later use. After the specimen melts, it still maintains a temperature of 2-8 ° C. Add a certain amount of PBS (PH7.4) and homogenize the specimen with a manual or homogenizer. Centrifuge for about 20 minutes (2000-3000 rpm). Collect the supernatant carefully. After aliquoting, a portion is to be tested, and the rest is frozen for future use. 6. The specimen should be extracted as soon as possible after collection. The extraction should be carried out according to relevant literature. The experiment should be carried out as soon as possible after extraction. If the test cannot be performed immediately, the specimen can be stored at -20 ° C, but repeated freezing and thawing should be avoided. 7. Samples containing NaN3 cannot be detected because NaN3 inhibits the activity of horseradish peroxidase (HRP). Procedure 1. Dilution and loading of standard products: set 10 standard wells on the enzyme-coated plate, add 100 μl of standard products in the first and second wells, and then add in the first and second wells. 50μl of standard diluent, mix well; then take 100μl from the first well and the second well respectively to the third and fourth wells, then add 50μl of standard diluent to the third and fourth wells respectively, mix Evenly; then take 50μl each in the third and fourth wells and discard, then add 50μl each to the fifth and sixth wells, and then add 50ul of standard dilution solution to the fifth and sixth wells respectively, mix After mixing, take 50μl from the fifth and sixth wells and add them to the seventh and eighth wells respectively. Then add 50μl of the standard dilution solution to the seventh and eighth wells respectively. Take 50μl from the eighth well to the ninth and tenth wells, and then add 50μl of the standard dilution solution to the ninth and tenth wells respectively. After mixing, take 50μl from the ninth and tenth wells and discard. (After dilution, the volume of each well is 50μl, and the concentrations are 36ng / L, 24ng / L, 12ng / L, 6ng / L, 3ng / L). 2. Add samples: set up blank wells (the blank control wells do not add samples and enzyme reagents, the rest of the steps are the same) and the sample wells to be tested. Add 40μl of sample diluent to the test sample well of the enzyme-coated plate, and then add 10μl of the sample to be tested (the final dilution of the sample is 5 times). Add the sample and add the sample to the bottom of the well of the microplate, try not to touch the wall of the well, shake gently to mix. 3. Incubation: Seal the plate with a sealing plate and incubate at 37 ° C for 30 minutes. 4. Mixing solution: dilute 20 times concentrated washing liquid with distilled water 20 times and reserve. 5. Washing: Carefully peel off the sealing film, discard the liquid, spin dry, fill each well with the washing liquid, let it stand for 30 seconds and then discard, repeat this 5 times, pat dry. 6. Add enzyme: add 50μl of enzyme label reagent to each well, except blank well. 7. Incubation: The operation is the same as 3. 8. Washing: The operation is the same as 5. 9. Color development: add 50μl of developer A to each well, then add 50μl of developer B, mix gently, and develop color at 37 ° C in the dark 15 minutes. 10. Termination: Add 50 μl of stop solution to each well to stop the reaction (the blue color turns to yellow at this time). 11. Determination: Measure the absorbance (OD value) of each well in sequence with the blank air conditioner at zero and 450 nm wavelength. The measurement should be carried out within 15 minutes after adding the stop solution. Note: 1. The kit should be equilibrated at room temperature for 15-30 minutes before being taken out of the refrigerated environment. If the enzyme label coated plate is unopened, the strip should be stored in a sealed bag. 2. Crystals may be precipitated in the concentrated washing liquid, which can be heated and dissolved in a water bath during dilution, and the results will not be affected during washing. 3. The sampler should be used at each step of sample addition, and the accuracy should be regularly checked to avoid test errors. It is best to control the sampling time within 5 minutes. If there are many specimens, it is recommended to use a volley gun to add samples. 4. Please make a standard curve at the same time of each measurement, it is best to make a double hole. If the content of the test substance in the specimen is too high (the OD value of the sample is greater than the OD value of the first well of the standard well), please first dilute it with a certain multiple (n times) of the sample diluent and then determine it. When calculating, please multiply the total dilution Multiple (× n × 5). 5. The sealing film is limited to one-time use to avoid cross-contamination. 6. Please keep the substrate away from light. 7. Strictly follow the instructions, and the test results must be determined based on the reading of the microplate reader. 8. All samples, washing liquids and various wastes should be treated as infectious agents. 9. The components of different batches of this reagent shall not be mixed. 10. If it is different from the English manual, the English manual shall prevail. Calculation: take the concentration of the standard as the abscissa and the OD as the ordinate, draw a standard curve on the coordinate paper, and find the corresponding concentration from the standard curve according to the OD value of the sample; multiply by the dilution factor; or use the standard The linear regression equation of the standard curve is calculated by the concentration and OD value of the sample, the OD value of the sample is substituted into the equation, the sample concentration is calculated, and then multiplied by the dilution factor, which is the actual concentration of the sample. (This picture is for reference only) Kit performance: 1. The linear regression coefficient R of the sample and the expected concentration is 0.990 or more. 2. The batch and batch see should be less than 9% and 11% respectively. Detection range: 2ng / L -40ng / L Storage conditions and expiration date: 1. Storage of the kit: 2-8 ℃. 2. Validity: 6 months Shanghai Youteng Biological Technology Co., Ltd. is a professional biological reagent sales company.

If you are finding a reliable beauty and salon equipment manufacturer, please contact with us. We would provide the best quality beauty and salon products with competitive price to you.

 

We export in beauty and salon equipment has more than ten years of experience. We are a leading manufacturer, we export to abroad as follow:

Electric Facial Bed, Hydraulic Facial Bed, wood Facial Bed , Massage Table , facial bed, facial massage chair, Shampoo Chair , Barber Chair , styling chair, child chair, Waiting Chair, dressing mirror, reception table, pedicure spa, Nail Table , massage chair, master chair, kids salon equipment,kids barber chair,trolley, Bed Cover , footstep and cushion.

 

Salon Child Chair

Salon Child Chair,Kids Salon Chair,Mini Salon Child Chair,Children Chair With Rolling Wheels

ChaoHui Beauty Salon Equipment Co., Ltd. , https://www.chaohuibeauty.com